Show simple item record

dc.contributorRotary District 6440es_ES
dc.contributor.authorHanson, Gerald P.
dc.contributor.authorPalmer, Philip E.S.
dc.date.accessioned2016
dc.date.available2016
dc.date.issued2013
dc.identifier.urihttps://iris.paho.org/handle/10665.2/28421
dc.description.abstractPreface It was planned during preparation of the manual “Diagnostic Imaging in Clinics and Small Hospitals” (June 2011) to include detailed calculations on radiation shielding for a WHIS-RAD as an annex. However, the length of the radiation shielding calculations was such that it was decided that the manual would serve its purpose much better without any annexes. So this second manual, “Radiation Shielding for Clinics or Small Hospitals with a WHIS-RAD”, details the calculations used to determine the radiation shielding required for the minimum size room (16 square meters) that is acceptable for a WHIS-RAD X-ray unit. Adjoining spaces as well as various situations involving the staff, patients and the storage of X-ray sensitive materials (film and loaded cassettes/ digital receptors) are included. To determine the required shielding (Table 2), the calculations are based on the X-ray examinations of 3,000 patients per year as is common in small hospitals (WL=1), and also for many times that workload. Table 2, with its wide range of situations, is also a useful reference for comparing shielding requirements for similar installations...The information will be useful for health authorities, health care and non-profit donor organizations when resources are limited. Funds not spent on unnecessary radiation shielding can be better used for equipment and staffing.en_US
dc.language.isoenes_ES
dc.subjectRadiationes_ES
dc.subjectRadiation Protectiones_ES
dc.subjectHospitalses_ES
dc.titleRadiation Shielding for Clinics and Small Hospitals with a WHIS-RAD 2013en_US
dc.title.alternativeBlindaje contra radiaciones para clínicas y hospitales pequeños con un WHIS-RAD 2013es_ES
dc.typePublicationsen_US
dc.rights.holderPan American Health Organizationen_US
dc.contributor.corporatenamePan American Health Organizationen_US
dc.description.notesRotary and PAHO are jointly publishing on the Internet this Manual on “Radiation Shielding for Clinics and Small Hospitals with a WHIS-RAD”. The Manual is authored by Drs. Gerald Hanson and Philip E.S. Palmer who are internationally recognized for their work with PAHO and WHO (World Health Organization) in radiation safety and radiology. They have given pre-publication rights to Rotary District 6440 and PAHO to assure immediate availability of the information.en_US
paho.publisher.countryUnited Stateses_ES
paho.publisher.cityWashington, D.Ces_ES
paho.source.centercodeUS1.1es_ES
paho.relation.languageVersion10665.2/28422


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record